Investigation of the Relationship Amongst Refraction, Keratometric and Pachymetric Measurements - Original Article
PDF
Cite
Share
Request
Original Article
P: 92-96
March 2008

Investigation of the Relationship Amongst Refraction, Keratometric and Pachymetric Measurements - Original Article

Turk J Ophthalmol 2008;38(2):92-96
1.
2.
3.
No information available.
No information available
Received Date: 06.11.2007
Accepted Date: 28.03.2008
PDF
Cite
Share
Request

ABSTRACT

Conclusions:

Males had lower keratometric measurements and were more likely to be hyperopic or mix hyperopic astigmatism than female. Females were more mix myopic astigmatism than males. CCT was higher in high hyperops and low in high myopes. A negative linear correlation between the keratometric measurements and SE was found. We believe that, investigation of these parameters would be helpful in better understanding of the biometric characteristics of the eye and choosing the appropriate technique in refractive surgery.

Results:

The relation between the age of the patients and CCT, and keratometric measurements were not statistically significant (p=0.598, p=0.403) respectively. While CCT were higher in male p=0.002), keratometric values were higher in female (p=0.0001). Spherical equivalent (SE) showed a correlation with CCT values (p=0.04), and a negative lineer correlation with the keratometric values (p=0.0001). While females were found to be more myopic, males were more hyperopic (p=0.0001). CCT were higher in the eyes those >+5.00 Diopter(D) (p=0.04), and keratometric values were higher in the eyes those less than -6.00 D (p=0.0001).

Methods:

A retrospective study of the subjective refraction of 1022 eyes of 511 consecutive subjects who presented for refractive surgery evaluation was performed. Of the subjects, 241(48%) were male and 270(52%) were female. Mean age of male and female were 32.1±9 and 30.1±8.1 respectively. Javal Keratometer was used for keratometric measurements. CCT was obtained with DGH 4000B A-Scan/Pachymeter. The statistical forecasting methods used are Mann-Whitney U-test, Spearman Correlation, Wilcoxon signed rank test, Kruskal-Wallis methods as implemented in the software package SPSS version 11.5. A p-value of <0.05 was considered to be statistically significant.

Purpose:

To investigate the relationship amongst refraction, central corneal thickness (CCT) and keratometric measurements.

Keywords:
Central corneal thickness, keratometry, pachymetry, refractive error

References

1
Rufer F, Schroder A, Arvani MK et al. Central and peripheral corneal pachymetry--standard evaluation with the Pentacam system. Klin Monatsbl Augenheilkd. 2005;222(2): 117-22.
2
Olsen T, A rnarsson A, Sasaki H et al. On the ocular refractive components: the Reykjavik Eye Study. Acta Ophthalmol Scand. 2007; 85(4): 361-6.
3
Satıcı A, Alçelik T. Kornea kırma gücünün yaş ile ilişkisi. MN-Oftalmoloji Dergisi 1997;4(1): 30-32.
4
Touzeau O, Allouch C, Borderie V et al. Correlation between refraction and ocular biometry. J Fr Ophtalmol. 2003; 26(4):355-63.
5
Esen E, Özdemir G, Özdemir N. Merkezi kornea kalınlıgı ile refraksiyon ilişkisi. Glokom-Katarakt 2006; 1 (1): 53-55.